Hospital & Healthcare Glazing Contractor — Washington DC, MD & VA
Healthcare glazing is judged on three things that ordinary commercial glazing never has to solve: radiation protection, infection control, and patient safety.
A lead-lined window that is installed with the wrong fastener pattern is a radiation problem. An observation window with a cleanable seal detail is an infection-control problem. We build both into the submittal, not the punch list.
- — Lead-lined and radiation-protection glazing coordinated with the shielding drawings
- — Ligature-resistant assemblies for behavioral health per current guidance
- — Occupied-facility installation with ICRA containment and negative-air sequencing

System selector
We install these published systems. Performance data below is the manufacturer's typical range, confirmed for your project before submittal.
Kawneer
Exterior patient-room glazing and interior observation windows.
Flush interior frame options suit clinical cleanability requirements.
Thermally broken exterior, non-thermal interior frames
Request spec sheetPublished data, test reports and warranty terms for Hospital & Healthcare Glazing Contractor — Washington DC, MD & VA.
Technical specifications
Assembly values depend on the profile, glazing make-up and project wind load. These are the ranges we work within, with the governing test standard for each.
Code and test compliance
- FGI Guidelines
- Planning, design and construction requirements for healthcare facilities.
- IBC 2021 Chapter 24
- Safety glazing and glazing in hazardous locations.
- NFPA 80 / NFPA 101
- Fire-rated assemblies and life safety provisions.
- State radiation control regulations
- Shielding requirements verified with the facility physicist.
The edition enforced on your project is confirmed with the authority having jurisdiction during permit review.
| Performance metric | Typical range | Test standard |
|---|---|---|
| Lead equivalence | Per radiation protection drawings (commonly 1.5 – 2.0 mm Pb) | Project shielding design |
| U-factor (exterior) | 0.28 – 0.40 Btu/h·ft²·°F | NFRC 100 / IECC 2021 |
| Acoustic rating | STC 35 – 45 | ASTM E90 / E413 |
| Impact safety | Category I or II per location | CPSC 16 CFR 1201 / ASTM E330 |
| Cleanability | Flush, non-porous, sealed joints | FGI Guidelines / ICRA protocol |
| Ligature resistance | Assembly per behavioral health guidance | VA design guide / facility standard |
| Air infiltration | 0.06 – 0.10 cfm/ft² at 6.24 psf | ASTM E283 |
From bid to install
The same five steps on every project, whether it is one opening or a full facade.
- 01
Site measure
Openings are measured and shielding, privacy and ligature requirements confirmed with facility engineering before release.
- 02
Shop drawings
Frames, lead-lined assemblies, anchorage and cleanable seal details are submitted for facilities and clinical review.
- 03
Fabrication
Lead-lined and specialty assemblies are fabricated to the verified shielding requirement, with material certifications retained.
- 04
Installation
Work is sequenced inside ICRA containment, with temporary barriers and negative-air protection maintained for the full shift.
- 05
Warranty and closeout
Certifications, test reports and as-builts are delivered to facilities for the building record.
Frequently asked questions
Can you install glazing in an occupied hospital wing?
Yes, with ICRA containment, negative-air machines, sealed barriers and work windows agreed with the facility. Most hospital work we do happens overnight or in phased areas that stay clinically separated from patients.
What does lead-lined glazing actually require?
The glass carries a stated lead equivalence, but the frame, fasteners and joints have to preserve it. The assembly is verified against the radiation protection drawings, and the facility physicist signs off on the shielding, not the glazier.
What is ligature-resistant glazing?
An assembly designed so a patient cannot attach a ligature to frames, hardware, seals or joints. It is specified for behavioral health environments and differs from ordinary safety glazing in hardware and joint design, not just glass thickness.
How do you protect infection control during installation?
Containment barriers, negative air, HEPA filtration where required, daily cleaning and controlled material movement. The containment is inspected by facility staff before work starts.
Can hospital glazing be replaced without closing the department?
Usually yes, in phases. Each opening is made weather-tight and secure the same shift, and the next opening is not started until the previous one is closed out.
Do you provide the documentation hospitals require for closeout?
Yes: product certifications, lead equivalence documentation, test reports and as-builts, formatted for the facility record.
Request the specification package
System data, test reports and warranty terms, plus a takeoff against your drawings. Tell us the scope and the jurisdiction and we will respond with what the review will require.
Start an RFQ